9.2 Main switch and fuse panel

The main switch for the 12 V electrical system is located on the fuse panel as indicated in the diagram.

Switch off the current using the main switch in the following situations.

  • When leaving the boat unattended.

  • Before performing any electrical installation or maintenance work.

Improper alteration of overcurrent device ratings

May cause injury or equipment damage.

Never alter or modify the rated current amperage of overcurrent protective devices

Improper component amperage

May cause injury or equipment damage.

Never replace electrical appliances or devices with components which exceed the rated current amperage of the circuit.

Verify component rating before installation.

Electrical fault

If a fuse keeps popping after being reset, consult a qualified marine electrician.

The automatic bilge pump remains operational whenever the 12 V battery is attached to the electrical system, regardless of the position of the main switch.

The 12 V system uses an automatic main fuse, which enable the current to be switched back on following a circuit overload by pressing the fuse button down. The system also uses conventional blade fuses that must be replaced when they have blown.